Quatech SSP-100 User Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
3.3 Common Problems
Basic Configuration List Not Available:
A problem noted on some systems is after a basic configuration has been manually
selected is the basic configurations list for the SSP-100 is no longer available. The
solution to this problem is to check the “Use Automatic Settings” box and allow
Windows to reconfigure the SSP-100 card. The basic configurations list should once
again be visible.
Base I/O Address Resource Modification Not Allowed:
The SSP-100 can either be forced to use a “standard” base address for COM1 - COM4,
or it may be configured to allow Windows to assign the base address. Windows will
not allow the base I/O address resource to be modified if the SSP-100 is configured to
use a “standard” base address, since it is being forced to a certain value by definition.
The solution to enabling a user defined I/O address resource is to select a basic
configuration which allows Windows (and the user) to assign the base address.
SSP-100
User’s Manual
3-11
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 50 51

Comments to this Manuals

No comments